UV Ballasts for Standard Output Lamps (425mA)

Enhance Efficacy with Specialized Ballasts:Explore our extensive selection of ballasts tailored for standard-output germicidal ultraviolet lighting. Our advanced solutions are at the forefront of applications that prioritize effective air and water purification, along with surface disinfection. The precision-driven current of our ballasts is designed to facilitate an ideal balance of UV-C intensity and energy efficiency, delivering a potent defense against a spectrum of pathogens, including bacteria, viruses, and mold.

Designed for UV-C Efficacy:Our ballasts are not generic lighting components repurposed for UV use; they are conceived and crafted for the specific demands of UV-C applications in both industrial and commercial settings. They are built to withstand continuous use, supporting a 90°C Max Case Temp/50°C Max Ambient, ensuring reliability in various operational scenarios.

Synchronized Performance and Compatibility:We ensure that our ballasts are rigorously calibrated to power UV-C lamps in accordance with the specifications set by leading lamp manufacturers, promoting enhanced lamp longevity and consistent UV-C emission. This commitment to compatibility is vital for the thorough deactivation of harmful microorganisms.

Certified Safety and Innovative Protection:Compliance with UL standards is just the beginning for our UV-C ballasts, many of which also meet CE, CCC, C62.41, C82.11, EN61347, EN55015 certifications. We take pride in our patented safety features, including end-of-lamp-life protection, which underscores our commitment to delivering secure and reliable UV-C solutions. Trust in the Robertson legacy for dependable UV-C power that supports the effectiveness and safety of your purification processes, from the first use to the last.

Robertson Ultraviolet Ballasts for SO Lamps (425mA)

SO-Category
IAQ164G6MV

Electronic Instant Start Ballast (for Instant Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 1 39W-75W Lamp, 50-60Hz, wire harness connector (included with ballast)

IAQ230G6MV

Electronic Instant Start Ballast (for Instant Start Lamps), 425mA nominal lamp current with an Arc voltage between 40V-100V, Input voltage of 100-240Vac, for 2/1 12W-43W Lamp, 50-60Hz, wire harness connectors (included with ballast)

$94.95/EA
IAQ264G6MV

Electronic Instant Start Ballast (for Instant Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 2/1 39W-75W Lamps, 50-60Hz, wire harness connectors (included with ballast)

$94.95/EA
PAQ164G6MV

Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 1 41W-75W Lamp, 50-60Hz, wire harness connector (included with ballasts)

$66.95/EA
PAQ230G6MV

Electronic Program Start Ballast (for Preheat Lamps), 425mA nominal lamp current with an Arc voltage between 40V-100V, Input voltage of 100-240Vac, for 2/1 17W-43W Lamp, 50-60Hz, wire harness connectors (included with ballast)

$77.95/EA
PAQ264G6MV

Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 2/1 41W-75W Lamp, 50-60Hz, wire harness connectors (included with ballast)

$79.95/EA
PSM1GPH18DW24

EZ24, Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 16V-41V, Input voltage of 24Vac-24Vdc, for 1 8W-17W Lamp between a 4"-14" lamp length, 50-60Hz, dual entry connectors (no leads)

$36.95/EA
PSM2GPH15V12-24

Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 16V-51V, Input voltage of 12Vdc-24Vdc, for 1 6W-21W Lamp or 2 ea 6W-14W Lamps,, 50-60Hz, dual entry connectors (no leads)

PSM2GPH18MVDW

Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 24V-96V, Input voltage of 120-277Vac, for 2/1 11W-25W Lamps or for 1 26W-38W Lamp, 50-60Hz, dual entry connectors (no leads)

$38.95/EA
PSM2GPH24IV

Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 24V-92V, Input voltage of 100-277Vac, for 2/1 10W-21W Lamps or for 1 22W-38W Lamp, Remote Turn On/Off and PLC/Relay Drive functionality, 1-10V input dimming control, 50-60Hz, poke-in connectors (easy release)

$43.95/EA
PSM2GPH24IVL

Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 24V-92V, Input voltage of 100-277Vac, for 2/1 10W-21W Lamps or for 1 22W-38W Lamp, 50-60Hz, poke-in connectors (easy release)

$40.95/EA
RSN1GPH20120

Electronic Preheat-Rapid Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 24V-47V, Input voltage of 120Vac, for 1 10W-20W Lamp, 50-60Hz

$19.95/EA
RSW240V120

Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 86V-102V, Input voltage of 120 Vac only, for 2/1 36W-40W Lamps, 50-60Hz, leads

$26.95/EA