Robertson Ultraviolet Ballasts
Advanced Solutions for Critical Purification Needs Robertson is at the forefront of developing sophisticated ballast technology, offering a comprehensive array of solutions for germicidal ultraviolet lighting. Our products are indispensable in applications that require the utmost in air and water purification and surface disinfection.
Tailored Technology for Peak UV-C Performance Our ballasts are not mere adaptations of general lighting components; they are designed with a singular focus on UV-C applications for industrial and commercial settings. They perform without issue in the most demanding duty cycles, including environments with stringent temperature requirements up to 90°C Max Case Temp and 50°C Max Ambient.
Engineered for Compatibility and Longevity Precision is key in our design process. Robertson ballasts are fine-tuned to power UV-C lamps according to the precise standards of industry-leading lamp manufacturers. This harmonization is not just about compatibility—it's about maximizing the lifespan of UV-C lamps while ensuring their peak output for effective pathogen control.
Certifications and Patented Innovations That Matter Every Robertson UV-C ballast carries the UL mark, with many models also possessing an array of international certifications such as CE, CCC, C62.41, C82.11, EN61347, and EN55015. Our patented end-of-lamp-life protection technology represents just one of the many breakthroughs we've made in pursuit of excellence.
The Robertson Commitment: Consistency Equals Success We believe in the power of consistent and reliable UV-C output—it's the cornerstone of successful pathogen eradication. The Robertson difference lies in our unwavering dedication to delivering that consistency throughout the life of your product.
Discover the superiority of Robertson ballasts and why our technology is the trusted choice for professionals who cannot afford to compromise on quality and effectiveness.
All Ultraviolet Ballasts (165mA to 2.1A)
- UV Ballasts for Low Output Lamps (165mA-330mA)
- UV Ballasts for Standard Output Lamps (425mA)
- UV Ballasts for Medium Output Lamps (500mA-600mA)
- UV Ballasts for High Output Lamps (800mA)
- UV Ballasts - OPTIMUM Series (425mA and 800mA)
- Replacement UV Ballasts for Aquafine OptiVenn and Trojan 3000 Series
- UV Drivers for Amalgam Lamps (1.0A to 2.1A)
PSP2GPH48HOIV
Electronic Program Start Ballast (for Preheat Start Lamps), 800mA nominal lamp current with an Arc voltage between 23V-115V, Input voltage of 100-277Vac, for 2/1 18W-48W Lamps or for 1 49W-95W Lamp, Remote Turn On/Off and PLC/Relay Drive functionality, 1-10V input dimming control, 50-60Hz, poke-in connectors (easy release)
PAQ164G6MV
Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 1 41W-75W Lamp, 50-60Hz, wire harness connector (included with ballasts)
PAQ164G6HOMV
Electronic Program Start Ballast (for Preheat Start Lamps), 800mA nominal lamp current with an Arc voltage between 100V-180V, Input voltage of 100-240Vac, for 1 80W-155W Lamp, 50-60Hz, wire harness connector (included with ballasts)
PAQ230G6MV
Electronic Program Start Ballast (for Preheat Lamps), 425mA nominal lamp current with an Arc voltage between 40V-100V, Input voltage of 100-240Vac, for 2/1 17W-43W Lamp, 50-60Hz, wire harness connectors (included with ballast)
PSR2GPH55HOMV
Electronic Program Start Ballast (for Preheat Start Lamps), 800mA nominal lamp current with an Arc voltage between 51V-112V, Input voltage of 120-277Vac, for 2/1 35W-48W Lamps or for 1 49W-90W Lamp, 50-60Hz
PAQ264G6MV
Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 2/1 41W-75W Lamp, 50-60Hz, wire harness connectors (included with ballast)
IAQ164G6HOMV
Electronic Instant Start Ballast (for Instant Start Lamps), 800mA nominal lamp current with an Arc voltage between 100V-180V, Input voltage of 100-240Vac, for 1 80W-155W Lamp, 50-60Hz, wire harness connector (included with ballast)
PAQ230G6HOMV
Electronic Program Start Ballast (for Preheat Lamps), 800mA nominal lamp current with an Arc voltage between 40V-100V, Input voltage of 100-240Vac, for 2/1 32W-80W Lamp, 50-60Hz, wire harness connectors (included with ballast)
IAQ264G6MV
Electronic Instant Start Ballast (for Instant Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 2/1 39W-75W Lamps, 50-60Hz, wire harness connectors (included with ballast)
IAQ230G6MV
Electronic Instant Start Ballast (for Instant Start Lamps), 425mA nominal lamp current with an Arc voltage between 40V-100V, Input voltage of 100-240Vac, for 2/1 12W-43W Lamp, 50-60Hz, wire harness connectors (included with ballast)
PAQ1320AMV-2100
Electronic Program Start Ballast (for an Amalgam Preheat Start Lamp), 1800mA-2100mA nominal lamp current with an Arc voltage between 38V-149V, Input voltage of 110-240Vac, for 1 57W-320W Lamp, 50-60Hz, wire harness connectors (included with ballasts)
PAQ264G6HOMV
Electronic Program Start Ballast (for Preheat Start Lamps), 800mA nominal lamp current with an Arc voltage between 100V-180V, Input voltage of 100-240Vac, for 2/1 80W-155W Lamp, 50-60Hz, wire harness connectors (included with ballast)
IAQ264G6HOMV
Electronic Instant Start Ballast (for Instant Start Lamps), 800mA nominal lamp current with an Arc voltage between 100V-180V, Input voltage of 100-240Vac, for 2/1 80W-155W Lamp, 50-60Hz, wire harness connectors (included with ballast)
IAQ230G6HOMV
Electronic Instant Start Ballast (for Instant Start Lamps), 800mA nominal lamp current with an Arc voltage between 40V-100V, Input voltage of 100-240Vac, for 2/1 32W-80W Lamp, 50-60Hz, wire harness connectors (included with ballast)
IAQ164G6MV
Electronic Instant Start Ballast (for Instant Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 1 39W-75W Lamp, 50-60Hz, wire harness connector (included with ballast)
PSM2GPH15V12-24
Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 16V-51V, Input voltage of 12Vdc-24Vdc, for 1 6W-21W Lamp or 2 ea 6W-14W Lamps,, 50-60Hz, dual entry connectors (no leads)