Industrial Grade UV Ballasts for Critical Infrastructure
Experience the benefits of our industry recognized technologies

What differentiates us

Robertson ballasts are specifically designed for Ultraviolet lamp applications; ensuring optimal performance, and reliability, unlike competitors who repurpose general lighting ballasts.

  • Our product portfolio is comprised entirely of proprietary designs, ensuring the authenticity and superior quality of our products, without the need to resell third-party products
  • Our ballasts incorporate exclusively high-rated temperature components and power-efficient designs. This dedication to quality enables us to provide extended product warranties and ensure superior performance
  • We have a substantial customer base across various international markets, demonstrating the broad trust in our product quality
  • Our wide product range enables us to meet specific application requirements accurately with tailored precision
  • Our products are field-tested for reliability under harsh operating conditions, setting us apart in the industry
Unique Benefits to Qualified OEM's

Unique Benefits to Qualified OEM's

  • - U.S.-based engineering and technical support: Ensures quick and effective responses to any queries or issues
  • - Complimentary custom design collaboration: Allows for personalized solutions tailored to specific needs
  • - Rapid prototyping of new designs: Facilitates faster innovation and product development cycles
  • - Customized PCBA solution options: Provides flexibility and the ability to meet unique requirements
  • - Private labeling: Offers opportunities for brand visibility and recognition
  • - Inventory stock agreements: Ensures product availability and reduces lead times

For more information, please contact us at salesteam01@robertsonuvballast.com

Next Generation Products -

IQ SERIES UV DRIVERS WITH SCALABLE CONTROL TECHNOLOGY

Each product in our iQ Series is a Program Start cULus recognized and CE compliant chassis, powered by a microprocessor-controlled driver. All iQ Series products feature stop/start/dim capabilities and RS485 communication, providing real-time information on ballast and lamp status, lamp current, and voltage per channel, as well as a lamp hours counter. They also offer a variable preheat time between four to twelve seconds for added flexibility.

The iQ Series includes drivers with lamp currents ranging from 425 mA to 2.1 A and is available in both 2-channel and 4-channel versions. These microprocessors can be networked to manage up to 1,020 addressable lamps, demonstrating their scalable control technology. The system operates via firmware on the micro daughter board, communicating with the 'Robertson Exerciser' on a PC through a USB connection. Our published protocol enables easy interface to existing PLC systems.

Contact salesteam01@robertsonuvballast.com for more information.

iQ-Ballast PC Control Panel Function Descriptions

iQ-Ballast PC Control Panel Function Descriptions
1.)
RS485 terminal

Select communication port in PC, tab “OPEN” to activate.

2.)
All

Control command applys to all ballast from #1 to #254.

3.)
Ranges

Control command applys to ballast in the range specified from “Addr start” to “Addr end”.

4.)
Addr start

Address is preset by 8-pole dip switch at ballast control board.
Address range: 1- 254.

5.)
Addr end

Ballast ending address.
Address is preset by 8-pole dip switch at ballast control board.
Address range: 1- 254.

6.)
Specified unit

Control command applys to a single specified address.

7.)
Set lamp current dimming level

Set lamp current dimming level from 50% to 100% by entering numbers from 50 to 100, tab “setting” to activate.

8.)
Lamp on/off control

Turn lamp on by tabing “ON”, tab the same box again to turn lamp off.

9.)
Individual lamp selection or applys to all lamps

Set dimming level to or turn on/off a dedicated lamp by tabing “Lamp1” to “Lamp4”, or applys to all lamp by tabing “All”.

10.)
Preheat time setting

Set lamp filament preheat time from 4 seconds to 12 seconds, this is applied to all lamps.

11.)
Lamp life setting

Uncheck “lock” box, set target lamp life for all lamps in terms of hours, max 100K hours.
Check “lock” box to prevent accidentally modification on lamp life setting.

12.)
Lamp on duration time display

Shows number of actual running hours for each lamp.
Lamp actual running number turns RED when it reaches target hours.

13.)
Clear

To reset lamp on duration time to zero when replacing a new lamp.

14.)
Status

LED signal for lamp status:
Lamp OnLED GreenLamp OffLED GrayNo LoadLED RedLamp EOL Shutdown

15.)
Real time lamp parameters monitoring, display only

• Dimming level = Present dimming level, in %
• Current = Lamp current, in Arms
• Voltages = Lamp voltage, in Vrms

16.)
Current Addr, display only

Shows the address of ballast being monitored.

17.)
Monitor

Tabing this button starts real time lamp parameters monitoring.

18.)
Serial communication message window

Message display window for trouble shooting in case of communication problem between ballast and PC. This is for software developer usage.

Spotlight

OPTIMUM HI-OUTPUT SERIES

Our new OPTIMUM HI-OUTPUT SERIES UV ballasts, specifically designed for UV-C HO lamps (800 mA), accommodate a power range from 18W to 95W with an input range of 100-277V (+/- 10%), or up to 155W at an input voltage range of 220V-277V (+/- 10%). Available in both program start and instant start versions (75W-155W only), these ballasts also feature a remote relay driver circuit for seamless PLC integration and dimming/variable output capabilities for enhanced energy efficiency. All models adhere to the latest CE and European safety requirements, are RoHS 3 Compliant, cULus Listed, and designed to ensure reduced EMC emissions.

For more detail about these products and to compare their numerous advantages to the Advance Pure Volt series product line.

Learn More

COMPARE THE DIFFERENCES

ROBERTSON OPTIMUM HI-OUTPUT vs ADVANCE PureVOLT

Compare the differences